Relay module; 1 make contact; Manual/0FF/Auto switch                                               

                                              

Name Value Unit
Color  gray   
Conformity marking  CE   
Pollution degree (1)   
Rated voltage EN (1) [V]  250 
Rated surge voltage (1) [kV]  kV 
Pull-in time (typ.) [ms]  15  ms 
Mechanical life  10 x 106 switching operations   
Drop-out time (typ.) [ms]  ms 
Nominal input current (coil 20 °C)  19 mA   
Operating power  400 mW   
Input voltage range  VN -15 % ... +20 %   
Max. switching voltage  250 V AC   
Max. switching power (resistive)  4000 VA AC, resistance see load limit curve   
Recommended minimum load  > 100 mA / 12 V AC/DC   
Nominal operating mode  continuous duty   
Dielectric strength, contact-coil (AC, 1 min) [kVrms kVrms 
Dielectric strength open contact (AC, 1 min) [kVrms kVrms 
Mechanical life at max. load (resistance)  min. 100.000 switching operations   
Nominal input voltage (VN 24 V DC   
Max. continuous current  16 A   
Max. make current (resistive) at 10 % OT *  120 A at 230 VAC (50 ms)   
Current input at rated voltage (coil 20 °C)  19 mA   
Max. make current  120 A at 230 VAC (50 ms)   
Connection technology (1)  CAGE CLAMP®   
Cross section from (1) [mm?]  0.08  mm? 
Cross section up to (1) [mm?]  2.5  mm? 
Cross section from (1) [AWG]  28  AWG 
Cross section up to (1) [AWG]  14  AWG 
Stripped length from (1) [mm]  mm 
Stripped length up to (1) [mm]  mm 
Stripped length (1) [in]  0.22  in 
Contact material  Ag alloy   
Weight [g]  55.6 
Width [mm]  17.5  mm 
Width [in]  0.689  in 
Height [mm]  55  mm 
Height [in]  2.165  in 
Length [mm]  90  mm 
Length [in]  3.543  in 
Storage temperature  -40 °C ... +70 °C   
Ambient operating temperature at VN  -25 °C ... +40 °C